digital audio
modular
processing system
C8000
switch over & ducking
Jünger Audio Studiotechnik GmbH
Justus-von-Liebig-Strasse 7
D -12489 Berlin
Germany
phone: +49-30-677721-0
fax: +49-30-677721-46
info@junger-audio.com
www.junger-audio.com
18/19
Error Detection An upstream module may insert a flag into each channel of the serial
audio data stream. If this flag is not detected, the Bus Status display
will turn red. If an upstream module does not insert such a flag you
must turn Error Detection Off in order to prevent non valid error
conditions.
to C8000 Bus
8Ch Mux Here you select a bus that will carry the outputs of the processor in the
order of Ch 1 – Ch 6. The positions for Ch 7 and Ch 8 are empty,
Ch 1/2 because the C8082 has only 6 outputs in 5.1 ducking mode while it
Ch 3/4 has only 4 outputs in 2x Stereo Ducking mode.
Ch 5/6 In parallel you may also assign a 2 Ch bus to one or all of the
processor outputs
Enable C8k Bus Driver You may turn off all bus drivers (put them into tri state mode) for
installation / testing to prevent conflicts with modules already in use.
See also BUS-EN switch (page 4)