Setup GUI – EVENTS – Triggers – Sources Parameters
Above is an example of parameter trigger sources. The phrase <multiple values> indicates that more
than one value of the parameter "Status" is bound to that trigger source:
If you click into the "Expression 1" box you see two greenish marked entries.
I.e. if one of these values is true, "Expression 1" is true.
Setup GUI – EVENTS – Triggers – Configuration Trigger Equation
To form a trigger you may logically combine two trigger sources:
Trigger Here you define a name for the trigger ("Trigger 1").
Source 1 The first source of a logical combination of two trigger sources.
Invert [ON / OFF]
If the type of trigger allows an inverted operation it can be defined here.
Type [GPI / Hot Key, Network / Parameter / Event active / Trigger effective/
Bypass / Sync Lock]
Source [e.g. for GPIs it will be 1 … 8]
It acts like an index for the trigger type (In case of GPI it is the physical
GPI number or in case of X*AP RM1 Hotkeys it is the key number ….
Logic [and / or / xor]
The kind of logical operation.
Source 2 Second source for the logical combination of two trigger sources.
If only one source exists, you may leave it unassigned [-].